Detail of steel bracing supporting the Colombo Street overpass. The photographer comments, "After the earthquake in Christchurch the Colombo St overpass got damaged and they used reinforcing steel beams to hold it up".
A photograph of a steel beam from 116 Lichfield Street.
A photograph of St John the Baptist Church with steel bracing holding up one side.
A black and white photograph of a steel structure on a demolition site filled with building rubble.
A photograph of the steel bracing which is holding up one side of St John the Baptist Church.
A photograph of the steel bracing which is holding up one side of St John the Baptist Church.
A photograph of Deans farm buildings on Kahu Road. Steel bracing has been used to hold the walls together.
A photograph of Deans farm buildings on Kahu Road. Steel bracing has been used to hold the walls together.
A photograph of Deans farm buildings on Kahu Road. Steel bracing has been used to hold the walls together.
A photograph of Deans farm buildings on Kahu Road. Steel bracing has been used to hold the walls together.
A photograph of Deans farm buildings on Kahu Road. Steel bracing has been used to hold the walls together.
Damage to the front of the Cathedral. Steel bracing supports the front and the rose window has been removed.
A photograph of Deans farm buildings on Kahu Road. Steel bracing has been used to hold the walls together.
A photograph of St John the Baptist Church. The side of the building is being held up by steel bracing.
The west face of the damaged ChristChurch Cathedral. Steel bracing supports the wall where the Rose Window has collapsed.
A cartoon based on a combination of logos of the Southern Steel and Queensland Firebirds netballs teams. The teams played each other in March 2011. Quantity: 1 digital cartoon(s).
Extended Direct Analysis (EDA), developed at the University of Canterbury, is an advance on the AISC Direct Analysis method for the analysis of frames subjected to static forces. EDA provides a faster, simple and more rational way to properly consider the second-order effects, initial residual stresses (IRS) and the initial imperfections or steel structures under one directional loading than conventional analysis methods. This research applied the EDA method to quantify the effect of member overstrength on frame behaviour for a single storey frame. Also, the effects of IRS, which were included in the EDA static analysis, but which are not considered explicitly in non-linear seismic analysis, were evaluated in two ways. Firstly, they were considered for simple structures subject to increasing cyclic displacement in different directions. Secondly, incremental dynamic analysis with realistic ground motion was used to quantify the likely effect of IRS in earthquakes. It was found that, contrary to traditional wisdom and practice, greater member strengths can result in lower frame strengths for frames under monotonic lateral loading. The structural lateral capacity of the overstrength case was reduced by 6% compared to the case using the dependable member strengths. Also, it resulted significantly different in member demands. Therefore, it is recommended that when either plastic analysis or EDA is used, that both upper and lower bounds on the likely member strength should be considered to determine the total frame strength and the member demands. Results of push-pull analysis under displacement control showed that for IRS ratio, gamma < 0.5 and axial compressive force ratio, N*/Ns, up to 0.5, IRS did affect the structural behaviour in the first half cycle. However, the behavior in the later cycles was not significantly affected. It also showed that the effect of initial residual stresses in the frame was less significant than for the column alone when the column was subjected to similar axial compressive force. The incremental dynamic analysis results from both cantilever column and the three-storey steel frame showed that by increasing gamma = 0 to 0.5, the effect of IRS on seismic responses, based on the 50% confidence level, was less than 3% for N*/Ns, up to 0.5.
Steel bracing on the Moorhouse Avenue overpass. The photographer comments, "Standing underneath I did hear a clump as if a part of the road overhead was pivoting as a car passed over it".
A view down Worcester Boulevard. Steel bracing against Our City O-Tautahi can be seen. The Cathedral can be seen at the end of the street and the Clarendon Tower on the right.
The wall of the Carlton Hotel has crumbled, exposing the interior of the upstair rooms. Scaffolding and steel bracing has been put up on the side, and a pile of building rubble can be seen on the footpath.
The wall of the Carlton Hotel has crumbled, exposing the interior of the upstair rooms. Scaffolding and steel bracing has been put up on the side, and a pile of building rubble can be seen on the footpath.
The NMIT Arts & Media Building is the first in a new generation of multistorey timber structures. It employs an advanced damage avoidance earthquake design that is a world first for a timber building. Aurecon structural engineers are the first to use this revolutionary Pres-Lam technology developed at the University of Canterbury. This technology marks a fundamental change in design philosophy. Conventional seismic design of multi-storey structures typically depends on member ductility and the acceptance of a certain amount of damage to beams, columns and walls. The NMIT seismic system relies on pairs of coupled LVL shear walls that incorporate high strength steel tendons post-tensioned through a central duct. The walls are centrally fixed allowing them to rock during a seismic event. A series of U-shaped steel plates placed between the walls form a coupling mechanism, and act as dissipators to absorb seismic energy. The design allows the primary structure to remain essentially undamaged while readily replaceable connections act as plastic fuses. In this era where sustainability is becoming a key focus, the extensive use of timber and engineered-wood products such as LVL make use of a natural resource all grown and manufactured within a 100km radius of Nelson. This project demonstrates that there are now cost effective, sustainable and innovative solutions for multi-story timber buildings with potential applications for building owners in seismic areas around the world.