Search

found 13 results

Images, Alexander Turnbull Library

A man has climbed an active volcano and pitched a tent in order to get away from the Canterbury earthquake and the flooding in the lower North Island. Refers to the Christchurch earthquake of 4th September 2010 as well as the heavy rain, slips, and flooding from Whanganui in the centre of the North Island down to the Rimutaka Hill Road, North of Wellington. Quantity: 1 digital cartoon(s).

Images, eqnz.chch.2010

Oxford Terrace Baptist Church on the corner of Madras St and Oxford Terrace, and alongside the Central City Fire Station on Kilmore St. The organ pipes have been saved and safely removed into safe keeping by the South Island Organ Company.

Images, UC QuakeStudies

Photograph captioned by Fairfax, "Chris Lin and his wife Caleen Xue at the door of their cool store safe where they slept for three weeks after the 4 September earthquake to guard what was left of their stock, while their teenage children rented a single room in a house up the road for their safety".

Images, UC QuakeStudies

Photograph captioned by Fairfax, "Chris Lin and his wife Caleen Xue at the door of their cool store safe where they slept for three weeks after the 4 September earthquake to guard what was left of their stock, while their teenage children rented a single room in a house up the road for their safety".

Videos, UC QuakeStudies

A video about the New Zealand Police and the New Zealand Army working in Christchurch to keep the city safe following the 4 September 2010 earthquake. The video includes an interview with Senior Sergeant Phillip Dean, Captain Mark Rutledge, Lance Corporal Aaron Tuhi, Lieutenant Dennis Petre, and Second Lieutenant David Pedrosa-Durie. It also includes footage of the New Zealand Military preparing meals at Burnham Camp.

Research papers, University of Canterbury Library

Research Report: 2010-02 The objective in writing this report is to provide a guide to structural engineers on how to assess the potential seismic performance of existing hollow-core floors in buildings and the steps involved in the design of new floors. Hollow-core units in New Zealand do not contain stirrups within the precast concrete section. This is due to the way that they are manufactured. The only reinforcement in the great majority of hollow-core units consists of pretensioned strands that are located close to the soffit. A consequence of this is that hollow-core units have a number of potential brittle failure modes that can occur when adverse structural actions are induced in the units. These adverse actions can be induced in a major earthquake due to the relative vertical, horizontal and rotational displacements that occur between hollow-core units and adjacent structural elements, such as beams or structural walls. A number of large scale structural tests backed up by analytical research has shown that extensive interaction occurs between floors containing prestressed precast units and other structural elements, such as walls and beams. The constraint that prestressed units in a floor can apply to adjacent beams can result in an increase in strength of the beams to a considerably greater strength than that indicated in editions of the New Zealand Structural Concrete Standard published prior to 2006. The extent of this increase is such that it could in some cases result in the development of a non-ductile failure mechanism instead of the ductile failure mechanism assumed in the design. Prestressed floor units tie the floor bays together leaving a weak section where the floor joins to supporting structural elements. The restraint provided by the prestress restricts the opening of cracks within the bay. In the event of an earthquake this restraint can result in wide cracks developing at some of the boundaries to floor bays. These cracks may have a significant influence on the performance of the floor when it acts as a diaphragm to transfer seismic forces to the lateral force resisting structural elements in the building. The report contains details of; 1. The different failure modes, which may be induced in hollow-core floors, and the failure modes that may develop in a buildings due to the presence of hollow-core units in the floors; 2. Criteria that may be used to assess the magnitude of the design earthquake which may be safely resisted by a hollow-core floor in a building; 3. Details of how construction practice related to the use of hollow-core floors in New Zealand has changed over the last five decades. This highlights particular aspects that need to be considered in carrying out an assessment of existing hollow-core floors; 4. Information on how a new hollow-core floor may be designed to be consistent with the Earthquake Actions Standard, NZS1170.5: 2004 and the Structural Concrete Standard, NZS3101: 2006 (plus Amendment 2); 5. A review of the research findings relevant to the behaviour of New Zealand hollow-core floors under earthquake conditions. Research that was used to develop the assessment and design criteria is described together with details of how the different criteria were developed from this work.