Audio, Radio New Zealand

After lengthy construction and Covid-19 delays, a centrepiece in Christchurch's earthquake rebuild will finally open its doors today. The $475 million convention centre called Te Pae is already booked to host 150 events next year, but they're not expected to be money-makers. Reporter Jean Edwards took a tour.

Audio, Radio New Zealand

Te Pae, Christchurch's near $450 million convention centre, has been officially opened this afternoon with a pōwhiri and unveiling by Mayor Lianne Dalziel and Minister Megan Woods. Billed as a legacy for the city, it replaces the old centre which was demolished following the Canterbury earthquakes. Niva Chittock is at the ceremony and joins Lisa with the details.

Audio, Radio New Zealand

Sir Richard Hadlee is seeking public support to fund the final 1.6 million dollars needed to open an indoor training facility that will bear his name in Christchurch's Hagley Park. The multipurpose venue will cost close to 5 million to construct. It will be the first indoor cricket training facility in the city since the earthquakes, and Sir Richard hopes that it will be open in 100 days time - for the start of next year's women's cricket World Cup. Hadlee, who was diagnosed with Colorectal cancer in 2018, told Felicity Reid it's a project that he's proud to be involved in. And he's also got a few thoughts on how the Black Caps will fare in India when the first Test starts tomorrow.

Research papers, University of Canterbury Library

Low Damage Seismic Design (LDSD) guidance material being developed by Engineering NZ is considering a design drift limit for multi-storey buildings of 0.5% at a new damage control limit state (DCLS). The impact of this new design requirement on the expected annual loss due to repair costs is investigated for a four-storey office building with reinforced concrete walls located in Christchurch. The LDSD guidance material aims to reduce the expected annual loss of complying buildings to below 0.1% of building replacement cost. The research tested this expectation. Losses were estimated in accordance with FEMA P58, using building responses from non-linear time history analyses (performed with OpenSees using lumped plasticity models). The equivalent static method, in line with NZS 1170.5 and NZS 3101, was used to design the building to LDSD specifications, representing a future state-of-practice design. The building designed to low-damage specification returned an expected annual loss of 0.10%, and the building designed conventionally returned an expected annual loss of 0.13%. Limitations with the NZS 3101 method for determining wall stiffness were identified, and a different method acknowledging the relationship between strength and stiffness was used to redesign the building. Along with improving this design assumption, the study finds that LDSD design criteria could be an effective way of limiting damage and losses.