Shirley Community Centre, Shirley Road, Christchurch. File reference: CCL-2012-05-10-Around-Shirley-May-2012 DSC_02866.JPG From the collection of Christchurch City Libraries.
Shirley Community Centre, Shirley Road, Christchurch. File reference: CCL-2012-05-10-Around-Shirley-May-2012 DSC_02862.JPG From the collection of Christchurch City Libraries.
Shirley Community Centre, Shirley Road, Christchurch. File reference: CCL-2012-05-10-Around-Shirley-May-2012 DSC_02869.JPG From the collection of Christchurch City Libraries.
Shirley Community Centre, Shirley Road, Christchurch. File reference: CCL-2012-05-10-Around-Shirley-May-2012 DSC_02863.JPG From the collection of Christchurch City Libraries.
Shirley Community Centre, Shirley Road, Christchurch. File reference: CCL-2012-05-10-Around-Shirley-May-2012 DSC_02867.JPG From the collection of Christchurch City Libraries.
Register Record for Shirley Community Centre, 10 Shirley Road, Christchurch.
Building Record Form for Shirley Community Centre, 10 Shirley Road, Christchurch.
Road workers digging earth out of a drain on Shirley Road near KFC. In the distance, the Palms shopping centre can be seen.
As part of a seismic retrofit scheme, surface bonded glass fiber-reinforced polymer (GFRP) fabric was applied to two unreinforced masonry (URM) buildings located in Christchurch, New Zealand. The unreinforced stone masonry of Christchurch Girls’ High School (GHS) and the unreinforced clay brick masonry Shirley Community Centre were retrofitted using surface bonded GFRP in 2007 and 2009, respectively. Much of the knowledge on the seismic performance of GFRP retrofitted URM was previously assimilated from laboratory-based experimental studies with controlled environments and loading schemes. The 2010/2011 Canterbury earthquake sequence provided a rare opportunity to evaluate the GFRP retrofit applied to two vintage URM buildings and to document its performance when subjected to actual design-level earthquake-induced shaking. Both GFRP retrofits were found to be successful in preserving architectural features within the buildings as well as maintaining the structural integrity of the URM walls. Successful seismic performance was based on comparisons made between the GFRP retrofitted GHS building and the adjacent nonretrofitted Boys’ High School building, as well as on a comparison between the GFRP retrofitted and nonretrofitted walls of the Shirley Community Centre building. Based on detailed postearthquake observations and investigations, the GFRP retrofitted URM walls in the subject buildings exhibited negligible to minor levels of damage without delamination, whereas significant damage was observed in comparable nonretrofitted URM walls. AM - Accepted Manuscript