8-pages High-Force-to-Volume lead dampers (HF2V) have been recently developed through an experimental research program at University of Canterbury – New Zealand. Testing of the device and applications on beam column joints have demonstrated stable hysteretic behaviour with almost no damage. This paper reports testing of HF2V devices with straight, bulged and constricted shaft configurations subjected to velocities of 0.15 - 5.0mm/s. The effect of the shaft configuration on the hysteresis loop shape, design relationships and the effect of the velocity on the resistive force of the device are described. Results show that hysteresis loop shape of the device is almost square regardless of the shaft configuration, and that devices are characterized by noticeable velocity dependence in the range of 0.15-1.0mm/s.
8-pages Due to the extreme damage seen in several recent earthquakes, several passive energy dissipation devices have been developed with different mechanisms of energy dissipation. Response spectra analysis across multiple earthquake suites is used to investigate the reductions in structural response and base shear forces to probabilistically assess the impact of these devices using suites of ground motions from the SAC project. Single-degree-of-freedom spectral analysis structures are used with nonlinear models of the sliding hinge joint (SHJ) and HF2V devices. Reduction factors are computed for each device compared to a linear, no-device structure. Force capacity for SHJ and HF2V devices are equivalent. Results are presented as 5th, 25th, median (50th), 75th and 95th percentile responses at each period (0.1-5.0s by 0.1s increments). Both devices show significant reductions in displacement at all spectral periods of 30- 60% (at median). Both increase base shear forces. However, SHJ systems show both a broader 5-95th percentile range, as well as larger increases in base shear due to their different velocity dependence in dissipating energy. The results provide initial design trade-off information in a probabilistic, performance-based framework for these devices.
8-pages Special devices can be used to minimize structural damage by energy dissipation or seismic isolation. This research considers High Force-to-Volume (HF2V), Symmetric Friction Connection (SFC), Asymmetric Friction Connection (AFC) and Linear-Elastic Isolators (LEI). Device architectures connecting column-to-deck and ground-to-deck are also compared. Bridge columns are assumed to remain elastic. Performance of bridge columns (peak and residual displacement) under 20 probabilistically scaled ground motions is assessed in spectral analysis (0.1-5.0sec) using reduction factors compared to a fixed, no-device case. Energy dissipating devices have minimum column displacement reduction factors when placed between the column and the deck for rigid connection system periods up to ~2.5s. Above that fundamental period, dissipating devices connecting ground-to-deck provide the optimum configuration. Residual displacements obtained when the energy dissipators are placed between the column and the deck are larger than those of the ground to deck case for periods below ~3.7s. Above this 3.7s, frictional dissipators in the column to deck case are more efficient, but HF2V devices connecting ground to deck remain as the best alternative with no residual displacements. The performance curves obtained in this research provide design guidelines for the best device and configuration applicable to a broad range of bridge structures.