A photograph of Speakers' Corner, an event that gathered citizens, architects, urbanists, developers and government officials to The Commons to speak about the importance of flexible and temporary spaces in the creation of cities. Speakers' Corner was part of FESTA 2014 and supported by Athfield Architects.
A photograph of Speakers' Corner, an event that gathered citizens, architects, urbanists, developers and government officials to The Commons to speak about the importance of flexible and temporary spaces in the creation of cities. Speakers' Corner was part of FESTA 2014 and supported by Athfield Architects.
A photograph of a participant in Speakers' Corner. Speakers' Corner was an event that gathered citizens, architects, urbanists, developers and government officials to The Commons to speak about the importance of flexible and temporary spaces in the creation of cities. Speakers' Corner was part of FESTA 2014 and supported by Athfield Architects.
A photograph of people sitting around a table at The Commons during Speakers' Corner, an event that gathered citizens, architects, urbanists, developers and government officials to speak about the importance of flexible and temporary spaces in the creation of cities. Speakers' Corner was part of FESTA 2014 and supported by Athfield Architects.
Based on a qualitative study of four organisations involving 47 respondents following the extensive 2010 – 2011 earthquakes in Christchurch, New Zealand, this paper presents some guidance for human resource practitioners dealing with post-disaster recovery. A key issue is the need for the human resource function to reframe its practices in a post-disaster context, developing a specific focus on understanding and addressing changing employee needs, and monitoring the leadership behaviour of supervisors. This article highlights the importance of flexible organisational responses based around a set of key principles concerning communication and employee perceptions of company support.
The connections between walls of unreinforced masonry (URM) buildings and flexible timber diaphragms are critical building components that must perform adequately before desirable earthquake response of URM buildings may be achieved. Field observations made during the initial reconnaissance and the subsequent damage surveys of clay brick URM buildings following the 2010/2011 Canterbury, New Zealand earthquakes revealed numerous cases where anchor connections joining masonry walls or parapets with roof or floor diaphragms appeared to have failed prematurely. These observations were more frequent for the case of adhesive anchor connections than for the case of through-bolt connections (i.e. anchorages having plates on the exterior façade of the masonry walls). Subsequently, an in-field test program was undertaken in an attempt to evaluate the performance of adhesive anchor connections between unreinforced clay brick URM walls and roof or floor diaphragm. The study consisted of a total of almost 400 anchor tests conducted in eleven existing URM buildings located in Christchurch, Whanganui and Auckland. Specific objectives of the study included the identification of failure modes of adhesive anchors in existing URM walls and the influence of the following variables on anchor load-displacement response: adhesive type, strength of the masonry materials (brick and mortar), anchor embedment depth, anchor rod diameter, overburden level, anchor rod type, quality of installation and the use of metal foil sleeve. In addition, the comparative performance of bent anchors (installed at an angle of minimum 22.5o to the perpendicular projection from the wall surface) and anchors positioned horizontally was investigated. Observations on the performance of wall-to-diaphragm connections in the 2010/2011 Canterbury earthquakes and a snapshot of the performed experimental program and the test results are presented herein. http://hdl.handle.net/2292/21050