Container wall protecting road from rock falls.
The wall alongside the Lyttelton Petanque Club.
Spray painted markings on a brick wall.
During the 2010/2011 Canterbury earthquakes, several reinforced concrete (RC) walls in multi-storey buildings formed a single crack in the plastic hinge region as opposed to distributed cracking. In several cases the crack width that was required to accommodate the inelastic displacement of the building resulted in fracture of the vertical reinforcing steel. This type of failure is characteristic of RC members with low reinforcement contents, where the area of reinforcing steel is insufficient to develop the tension force required to form secondary cracks in the surrounding concrete. The minimum vertical reinforcement in RC walls was increased in NZS 3101:2006 with the equation for the minimum vertical reinforcement in beams also adopted for walls, despite differences in reinforcement arrangement and loading. A series of moment-curvature analyses were conducted for an example RC wall based on the Gallery Apartments building in Christchurch. The analysis results indicated that even when the NZS 3101:2006 minimum vertical reinforcement limit was satisfied for a known concrete strength, the wall was still susceptible to sudden failure unless a significant axial load was applied. Additionally, current equations for minimum reinforcement based on a sectional analysis approach do not adequately address the issues related to crack control and distribution of inelastic deformations in ductile walls.
Slender precast concrete wall panels are currently in vogue for the construction of tall single storey warehouse type buildings. Often their height to thickness ratio exceed the present New Zealand design code (NZS 3101) limitations of 30:1. Their real performance under earthquake attack is unknown. Therefore, this study seeks to assess the dynamic performance of slender precast concrete wall panels with different base connection details. Three base connections (two fixed base and one rocking) from two wall specimens with height to thickness ratios of 60:1 were tested under dynamic loading. The two fixed based walls had longitudinal steel volumes of 1.27% to 0.54% and were tested on the University of Canterbury shaking table to investigate their proneness to out-of-plane buckling. Based on an EUler-type theoretical formula derived as part of the study, an explanation is made as to why walls with high in-plane capacity are more prone to buckling. The theory was validated against the present and past experimental evidence. The rocking base connection designed and built in accordance with a damage avoidance philosophy was tested on the shaking table in a similar fashion to the fixed base specimens. Results show that in contrast with their fixed base counterparts, rocking walls can indeed fulfil a damage-free design objective while also remaining stable under strong earthquake ground shaking.
The shadow mural painted by Jeremy Sauzier on the side of the building facing Gap Filler's Dance-O-Mat.
Photograph captioned by BeckerFraserPhotos, "Cannon Hill Crescent, Mt Pleasant".
Photograph captioned by BeckerFraserPhotos, "Te Awakura Terrace".
Photograph captioned by BeckerFraserPhotos, "Te Awakura Terrace".
Volunteers stepping back to admire the almost-completed "Knit Happens" mural.
Photograph captioned by BeckerFraserPhotos, "Te Awakura Terrace, Mt Pleasant".
Recent earthquakes have highlighted the vulnerability of existing structure to seismic loading. Current seismic retrofit strategies generally focus on increasing the strength/stiffness in order to upgrade the seismic performance of a structure or element. A typical drawback of this approach is that the demand on the structural and sub-structural elements can be increased. This is of particular importance when considering the foundation capacity, which may already be insufficient to allow the full capacity of the existing wall to develop (due to early codes being gravity load orientated). In this thesis a counter intuitive but rational seismic retrofit strategy, termed "selective weakening" is introduced and investigated. This is the first stage of an ongoing research project underway at the University of Canterbury which is focusing on developing selective weakening techniques for the seismic retrofit of reinforced concrete structures. In this initial stage the focus is on developing selective weakening for the seismic retrofit of structural walls. This is performed using a series of experimental, analytical and numerical investigations. A procedure for the assessment of existing structural walls is also compiled, based on the suggestions of currently available code provisions. A selective weakening intervention is performed within an overall performance-based retrofit approach with the aim of improving the inelastic behaviour by first reducing the strength/stiffness of specific members within the structural system. This will be performed with the intention of modifying a shear type behaviour towards a flexural type behaviour. As a result the demand on the structural member will be reduced. Once weakening has been implemented the designer can use the wide range of techniques and materials available (e.g. use of FRP, jacketing or shotcrete) to ensure that adequate characteristics are achieved. Whilst performing this it has to be assured that the structure meets specific performance criteria and the principles of capacity design. A target of the retrofit technique is the ability to introduce the characteristics of recently developed high performance seismic resisting systems, consisting of a self centring and dissipative behaviour (commonly referred to as a hybrid system). In this thesis, results of experimental investigations performed on benchmark and selectively weakened walls are discussed. The investigations consisted of quasi-static cyclic uni-directional tests on two benchmark and two retrofitted cantilever walls. The first benchmark wall is detailed as typical of pre-1970's construction practice. An equivalent wall is retrofitted using a selective weakening approach involving a horizontal cut at foundation level to allow for a rocking response. The second benchmark wall represents a more severe scenario where the inelastic behaviour is dominated by shear. A retrofit solution involving vertically segmenting the wall to improve the ductility and retain gravity carrying capacity by inducing a flexural response is implemented. Numerical investigations on a multi-storey wall system are performed using non linear time history analysis on SDOF and MDOF lumped plasticity models, representing an as built and retrofitted prototype structure. Calibration of the hysteretic response to experimental results is carried out (accounting for pinching and strength degradation). The sensitivity of maximum and residual drifts to p-delta and strength degradation is monitored, along with the sensitivity of the peak base shear to higher mode affects. The results of the experimental and analytical investigations confirmed the feasibility and viability of the proposed retrofit technique, towards improving the seismic performance of structural walls.
Graffiti on a damaged building. The photographer comments, "After some of the walls were demolished this graffiti was exposed. The next day this wall was gone as well".
The sea wall at Beachville Road, Redcliffs, after the earthquake. It used to be straight and level - not now! As a teenager I went fishing off this wall.
A 150 metre memorial wall will be unveiled on the banks of the Avon today six years after the devastating earthquake hit Christchurch. Bruce McEachen says it is an inspiring place and the wall will perform every function the families need it to.
A 150 metre memorial wall will be unveiled on the banks of the Avon today six years after the devastating earthquake hit Christchurch. Bruce McEachen says it is an inspiring place and the wall will perform every function the families need it to.
A photograph of the earthquake damaged M J Knowles Building on Tuam Street. The wall has either collapsed or been removed leaving the inside of the building exposed. Loose bricks from the wall cover the footpath.
A photograph of the earthquake damaged M J Knowles Building on Tuam Street. The wall has either collapsed or been removed leaving the inside of the building exposed. Loose bricks from the wall cover the footpath.
A photograph of a wall of a building on St Asaph Street which has collapsed onto the car park next door. Rubble and bricks from the top of the wall underneath have fallen on top.
A photograph of the earthquake damaged M J Knowles Building on Tuam Street. The wall has either collapsed or been removed leaving the inside of the building exposed. Loose bricks from the wall cover the footpath.
A photograph of an earthquake-damaged building on St Asaph Street. The brick wall of the gable has collapsed, and the bricks have fallen onto the pavement below. There is also damage to the wall on the left.
The Gospel Way Outreach Church in the process of being demolished on Charles Street. Down the side wall, a noticeable slump in the brick wall can be seen. This is probably why the building needed to be demolished.
One of the most fascinating things about studying and interpreting the past is the possibilities it holds. Could the broken tea cup I’ve found been smashed against a wall in a fit of rage after a wife found her husband … Continue reading →
The project report for Knit Happens, part of Gap Filler project 20, Walls. Knit Happens was a mural with a pattern reminiscent of a jersey. It was painted on the exposed wall of a brick building on Madras Street.
A view of the interior of the Durham Street Methodist Church hall. The floor has been coated with plaster from the walls and ceiling, and items of furniture have been stacked up around the walls.
A photograph of a damaged house has been reflected in the lower part of the image and digitally manipulated.
A photograph of the earthquake damaged M J Knowles Building on Tuam Street. The wall has either collapsed or been removed leaving the inside of the building exposed. Loose bricks from the wall cover the footpath.
A wall on the former site of Piko Wholefoods has been painted with the address of their new premises. A damaged part of the wall is covered with a graffiti paste-up of an elastoplast, with a speech bubble reading, "You poor thing".
A photograph of a room in the Diabetes Centre. The panelling has been removed from the walls, exposing the wooden framing, insulation, and wires underneath. Several drawer units have been stacked in the middle of the room.
A photograph of the Poetica Urban Poetry wall.