A thumbnail photograph of Whole House Reuse item 390, cropped for the catalogue. This item was salvaged from 19 Admiral Way in New Brighton as part of the Whole House Reuse project.
A thumbnail photograph of Whole House Reuse item 391, cropped for the catalogue. This item was salvaged from 19 Admiral Way in New Brighton as part of the Whole House Reuse project.
A photograph of Whole House Reuse item 399. This item was salvaged from 19 Admiral Way in New Brighton as part of the Whole House Reuse project.
Damage to the Hardie and Thomson timber storehouse on Sherborne Street. The sides of the wooden building have bowed outwards, and planks have come loose.
The side wall of a building on Worcester Street. Timber bracing has been placed along the top of the wall and black plastic to cover the gaps.
Dust and chips of plaster on the pews inside the Durham Street Methodist Church. One of the building's windows has been braced and weather proofed with timber.
A thumbnail photograph of Whole House Reuse item 403, cropped for the catalogue. This item was salvaged from 19 Admiral Way in New Brighton as part of the Whole House Reuse project.
A photograph of Whole House Reuse item 403. This item was salvaged from 19 Admiral Way in New Brighton as part of the Whole House Reuse project.
A model of the ChristChurch Transitional Cathedral made predominantly out of laser cut and engraved coloured acrylic as well as timber dowels to represent the cardboard tubes.
The seismic response of unreinforced masonry (URM) buildings, in both their as-built or retrofitted configuration, is strongly dependent on the characteristics of wooden floors and, in particular, on their in-plane stiffness and on the quality of wall-to-floor connections. As part of the development of alternative performance-based retrofit strategies for URM buildings, experimental research has been carried out by the authors at the University of Canterbury, in order to distinguish the different elements contributing to the whole diaphragm's stiffness. The results have been compared to the ones predicted through the use of international guidelines in order to highlight shortcomings and qualities and to propose a simplified formulation for the evaluation of the stiffness properties.
The recent Canterbury earthquake sequence in 2010-2011 highlighted a uniquely severe level of structural damage to modern buildings, while confirming the high vulnerability and life threatening of unreinforced masonry and inadequately detailed reinforced concrete buildings. Although the level of damage of most buildings met the expected life-safety and collapse prevention criteria, the structural damage to those building was beyond economic repair. The difficulty in the post-event assessment of a concrete or steel structure and the uneconomical repairing costs are the big drivers of the adoption of low damage design. Among several low-damage technologies, post-tensioned rocking systems were developed in the 1990s with applications to precast concrete members and later extended to structural steel members. More recently the technology was extended to timber buildings (Pres-Lam system). This doctoral dissertation focuses on the experimental investigation and analytical and numerical prediction of the lateral load response of dissipative post-tensioned rocking timber wall systems. The first experimental stages of this research consisted of component testing on both external replaceable devices and internal bars. The component testing was aimed to further investigate the response of these devices and to provide significant design parameters. Post-tensioned wall subassembly testing was then carried out. Firstly, quasi-static cyclic testing of two-thirds scale post-tensioned single wall specimens with several reinforcement layouts was carried out. Then, an alternative wall configuration to limit displacement incompatibilities in the diaphragm was developed and tested. The system consisted of a Column-Wall-Column configuration, where the boundary columns can provide the support to the diaphragm with minimal uplifting and also provide dissipation through the coupling to the post-tensioned wall panel with dissipation devices. Both single wall and column-wall-column specimens were subjected to drifts up to 2% showing excellent performance, limiting the damage to the dissipating devices. One of the objectives of the experimental program was to assess the influence of construction detailing, and the dissipater connection in particular proved to have a significant influence on the wall’s response. The experimental programs on dissipaters and wall subassemblies provided exhaustive data for the validation and refinement of current analytical and numerical models. The current moment-rotation iterative procedure was refined accounting for detailed response parameters identified in the initial experimental stage. The refined analytical model proved capable of fitting the experimental result with good accuracy. A further stage in this research was the validation and refinement of numerical modelling approaches, which consisted in rotational spring and multi-spring models. Both the modelling approaches were calibrated versus the experimental results on post-tensioned walls subassemblies. In particular, the multi-spring model was further refined and implemented in OpenSEES to account for the full range of behavioural aspects of the systems. The multi-spring model was used in the final part of the dissertation to validate and refine current lateral force design procedures. Firstly, seismic performance factors in accordance to a Force-Based Design procedure were developed in accordance to the FEMA P-695 procedure through extensive numerical analyses. This procedure aims to determine the seismic reduction factor and over-strength factor accounting for the collapse probability of the building. The outcomes of this numerical analysis were also extended to other significant design codes. Alternatively, Displacement-Based Design can be used for the determination of the lateral load demand on a post-tensioned multi-storey timber building. The current DBD procedure was used for the development of a further numerical analysis which aimed to validate the procedure and identify the necessary refinements. It was concluded that the analytical and numerical models developed throughout this dissertation provided comprehensive and accurate tools for the determination of the lateral load response of post-tensioned wall systems, also allowing the provision of design parameters in accordance to the current standards and lateral force design procedures.
A photograph of Whole House Reuse item 363. This item was salvaged from 19 Admiral Way in New Brighton as part of the Whole House Reuse project.
A photograph of Whole House Reuse item 364. This item was salvaged from 19 Admiral Way in New Brighton as part of the Whole House Reuse project.
A photograph of Whole House Reuse item 361. This item was salvaged from 19 Admiral Way in New Brighton as part of the Whole House Reuse project.
A photograph of Whole House Reuse item 362. This item was salvaged from 19 Admiral Way in New Brighton as part of the Whole House Reuse project.
A thumbnail photograph of Whole House Reuse item 362, cropped for the catalogue. This item was salvaged from 19 Admiral Way in New Brighton as part of the Whole House Reuse project.
A thumbnail photograph of Whole House Reuse item 363, cropped for the catalogue. This item was salvaged from 19 Admiral Way in New Brighton as part of the Whole House Reuse project.
A thumbnail photograph of Whole House Reuse item 361, cropped for the catalogue. This item was salvaged from 19 Admiral Way in New Brighton as part of the Whole House Reuse project.
A thumbnail photograph of Whole House Reuse item 364, cropped for the catalogue. This item was salvaged from 19 Admiral Way in New Brighton as part of the Whole House Reuse project.
A view across Lichfield Street to the historic Mayfair building. Masonry has collapsed from the top storey of the building and the resulting gaps have been weather proofed with timber and building paper.
A view across Lichfield Street to the historic Mayfair building. Masonry has collapsed from the top storey of the building and the resulting gaps have been weather proofed with timber and building paper.
Damage to a wooden building on Bealey Avenue. Windows on the lower storey are covered in tarpaulins. The photographer comments, "One large timber building stands, the dust from a demolition can be seen at right".
A video recording of a lecture presented by Professor Rajesh Dhakal and Professor Andy Buchanan as part of the 2011 University of Canterbury Earthquake Lecture Series.
The Seido Karate Shibu building on Barbadoes Street. The top section of the building has been weather proofed with plywood where the masonry has fallen away and its side has been braced with timber.
A section of the Cranmer Courts, facing Kilmore Street. Several windows have been broken and much of the cornice has fallen off. The apex of the roof has been reinforced with timber bracing.
A section of the Cranmer Courts, facing Kilmore Street. Several windows have been broken and much of the cornice has fallen off. The apex of the roof has been reinforced with timber bracing.
Windows of the Durham Street Methodist Church that have been braced and weather proofed with timber. The plaster around them is badly cracked, and a section has fallen away, revealing the brick work underneath.
The fence of a house on Robson Avenue in Avonside. Part of the breeze-block section at its base has collapsed in the 4 September 2010 earthquake, leaving only the timber part above it.
A photograph of the wall of a street football arena built by Student Volunteer Army volunteers. The wall has a sign attached acknowledging the support of Resene, and is painted with the words, 'Red zone timber'.
The brick chimney section of a house on Avonside Drive. Cracks can be seen between the bricks and the whole chimney has moved away from the rest of the house. It has been strengthened with timber bracing.