A photograph of a large-scale, temporary structure, titled Synthesis, being installed for CityUps. CityUps was a 'city of the future for one night only', and the main event of FESTA 2014.
The structure of the 10 square metre office building which is to serve as Gap Filler Headquarters is almost complete. A sign on the front reads, "Gap Filler project in progress on this site".
Cunningham House at the Christchurch Botanic Gardens is still closed due to earthquake damage. I wonder if it will ever re-open or suffer the demolition fate many other iconic structures in Christchurch have.
Between September 4, 2010 and December 23, 2011, a series of earthquakes struck the South Island of New Zealand including the city of Christchurch producing heavy damage. During the strongest shaking, the unreinforced masonry (URM) building stock in Christchurch was subjected to seismic loading equal to approximately 150-200% of code values. Post-earthquake reconnaissance suggested numerous failures of adhesive anchors used for retrofit connection of roof and floor diaphragms to masonry walls. A team of researchers from the Universities of Auckland (NZ) and Minnesota (USA) conducted a field investigation on the performance of new adhesive anchors installed in existing masonry walls. Variables included adhesive type, anchor diameter, embedment length, anchor inclination, and masonry quality. Buildings were selected that had been slated for demolition but which featured exterior walls that had not been damaged. A summary of the deformation response measured during the field tests are presented. AM - Accepted Manuscript
Many large-scale earthquakes all over the world have highlighted the impact of soil liquefaction to the built environment, but the scale of liquefaction-induced damage experienced in Christchurch and surrounding areas following the 2010-2011 Canterbury earthquake sequence (CES) was unparalleled, especially in terms of impact to an urban area. The short time interval between the large earthquakes presented a very rare occasion to examine liquefaction mechanism in natural deposits. The re-liquefaction experienced by the city highlighted the high liquefaction susceptibility of soil deposits in Christchurch, and presented a very challenging problem not only to the local residents but to the geotechnical engineering profession. This paper summarises the lessons learned from CES, and the impacts of the observations made to the current practice of liquefaction assessment and mitigation.
A photograph of a temporary structure titled ING being installed for CityUps - a 'city of the future for one night only', and the main event of FESTA 2014. ING was created by students from Unitec.
Aftermath of September 4th Earthquake in Canterbury. Shops on Colombo Street in Christchurch. The initial 7.1 quake has been followed by around 1590 aftershocks recorded to date - causing further damage to already weakened structures.
A photograph of a tower of the Arts Centre taken from Rolleston Avenue near the Botanic Gardens. A wooden structure has been wrapped around the tower and secured with tie-downs in order to help reduce damage by further aftershocks.
The damaged Knox Presbyterian Church on the corner of Victoria Street and Bealey Avenue. The brickwork in the gables of the building has crumbled onto the footpath below, exposing the wooden structure beneath and the inside of the church.
The badly-damaged Knox Presbyterian Church on the corner of Bealey Avenue and Victoria Street. The brickwork in the gables has crumbled, exposing the wooden structure underneath. Spray-painted USAR codes can be seen on the brick wall.
A video clip of two large-scale, temporary structures, titled Synthesis and Aurora, being installed by students from CPIT and Unitec. The installations were part of CityUps - a 'city of the future for one night only', and the main event of FESTA 2014.
The badly-damaged Knox Presbyterian Church on the corner of Bealey Avenue and Victoria Street. The brickwork in the gables has crumbled, exposing the wooden structure underneath. Wire fencing has been placed around the building as a cordon.
Damage to the north-west corner of the Cathedral of the Blessed Sacrament. The upper part of the corner structure has collapsed. A statue of the Virgin Mary can be seen in a window. The photographer comments, "A bike ride around the CBD. Catholic Cathedral, Barbadoes St".
The badly-damaged Knox Presbyterian Church on the corner of Bealey Avenue and Victoria Street. The brickwork in the gables has crumbled, exposing the wooden structure underneath. Wire fencing has been placed around the building as a cordon.
It's been revealed that not a single one of New Zealand's 315 police buildings constructed before 2011 have had a full earthquake safety check. Canterbury's district health buildings and a central Wellington cinema are among other major structures needing checks. Phil Pennington joins us with the details.
A PDF copy of The Star newspaper, published on Friday 10 February 2012.
Page 2 of Section A of the Christchurch Press, published on Saturday 1 October 2011.
A video about the Christchurch central city in the days after the 4 September 2010 earthquake. The video includes footage of empty streets, and New Zealand Police and Army members guarding the cordons. It also includes footage of engineers checking the safety of buildings.
Drywalls are the typical infill or partitions used in new structures. They are usually located within structural frames and/or between upper and lower floor slabs in buildings. Due to the materials used in their construction, unlike masonry blocks, they can be considered as light non-structural infill/partition walls. These types of walls are especially popular in New Zealand and the USA. In spite of their popularity, little is known about their in-plane cyclic behaviour when infilled within a structural frame. The cause of this lack of knowledge can be attributed to the typical assumption that they are weak non-structural elements and are not expected to interact with the surrounding structural system significantly. However, recent earthquakes have repeatedly shown that drywalls interact with the structure and suffer severe damage at very low drift levels. In this paper, experimental test results of two typical drywall types (steel and timber framed) are reported in order to gather further information on; i) their reverse cyclic behaviour, ii) inter-storey drift levels at which they suffer different levels of damage, iii) the level of interaction with the surrounding structural frame system. The drywall specimens were tested using quasi-static reverse cyclic testing protocols within a full scale precast RC frame at the Structures Laboratory of the University of Canterbury.
A series of undrained cyclic direct simple shear (DSS) tests on specimens of sandy silty soils are used to evaluate the effects of fines content, fabric and layered structure on the liquefaction response of sandy soils containing non-plastic fines. Test soils originate from shallow deposits in Christchurch, New Zealand, where severe and damaging manifestations of liquefaction occurred during the 2010-2011 Canterbury earthquakes. A procedure for reconstituting specimens by water sedimentation is employed. This specimen preparation technique involves first pluviation of soil through a water column, and then application of gentle vibrations to the mould (tapping) to prepare specimens with different initial densities. This procedure is applied to prepare uniform specimens, and layered specimens with a silt layer atop a sand layer. Cyclic DSS tests are performed on water-sedimented specimens of two sands, a silt, and sand-silt mixtures with different fines contents. Through this testing program, effects of density, time of vibration during preparation, fines content, and layered structure on cyclic behaviour and liquefaction resistance are investigated. Additional information necessary to characterise soil behaviour is provided by particle size distribution analyses, index void ratio testing, and Scanning Electronic Microscope imaging. The results of cyclic DSS tests show that, for all tested soils, specimens vibrated for longer period of time have lower void ratios, higher relative density, and greater liquefaction resistance. One of the tested sands undergoes significant increase in relative density and liquefaction resistance following prolonged vibration. The other sand exhibits lower increase in relative density and in liquefaction resistance when vibrated for the same period of time. Liquefaction resistance of sand-silt mixtures prepared using this latter sand shows a correlation with relative density irrespective of fines content. In general, however, magnitudes of changes in liquefaction resistance for given variations in vibration time, relative density, or void ratio vary depending on soils under consideration. Characterization based on maximum and minimum void ratios indicates that tested soils develop different structures as fines are added to their respective host sands. These structures influence initial specimen density, strains during consolidation, cyclic liquefaction resistance, and undrained cyclic response of each soil. The different structures are the outcome of differences in particle size distributions, average particle sizes, and particle shapes of the two host sands and of the different relationships between these properties and those of the silt. Fines content alone does not provide an effective characterization of the effects of these factors. Monotonic DSS tests are also performed on specimens prepared by water sedimentation, and on specimens prepared by moist tamping, to identify the critical state lines of tested soils. These critical state lines provide the basis for an alternative interpretation of cyclic DSS tests results within the critical state framework. It is shown that test results imply general consistency between observed cyclic and monotonic DSS soil response. The effects of specimen layering are scrutinised by comparing DSS test results for uniform and layered specimens of the same soils. In this case, only a limited number of tests is performed, and the range of densities considered for the layered specimens is also limited. Caution is therefore required in interpretation of their results. The liquefaction resistance of layered specimens appears to be influenced by the bottom sand layer, irrespective of the global fines content of the specimen. The presence of a layered structure does not result in significant differences in terms of liquefaction response with respect to uniform sand specimens. Cyclic triaxial data for Christchurch sandy silty soils available from previous studies are used to comparatively examine the behaviour observed in the tests of this study. The cyclic DSS liquefaction resistance of water-sedimented specimens is consistent with cyclic triaxial tests on undisturbed specimens performed by other investigators. The two data sets result in similar liquefaction triggering relationships for these soils. However, stress-strain response characteristics for the two types of specimens are different, and undisturbed triaxial specimen exhibit a slower rate of increase in shear strains compared to water-sedimented DSS specimens. This could be due to the greater influence of fabric of the undisturbed specimens.
A photograph of the Canterbury Provincial Chambers on Durham Street. The building has been cordoned off with wire fencing and the roof covered by plastic sheeting. Much of the masonry has been removed and a wooden structure constructed inside. A crane can be seen behind.
A photograph of the Arts Centre taken from Rolleston Avenue near the Botanic Gardens. The building has been cordoned off by wire fencing and a wooden structure has been secured to the tower with tie-downs to help reduce damage from further aftershocks.
Photograph captioned by Fairfax, "Owners of the Octagon hang models to decorate the structures holding up the tower of the building after earthquake damage. Chris Stead (left) from Theme Pro and stone mason Andy Carmichael from Cut'n'Carve Stone".
Photograph captioned by Fairfax, "Owners of the Octagon hang models to decorate the structures holding up the tower of the building after earthquake damage. Chris Stead (left) from Theme Pro and stone mason Andy Carmichael from Cut'n'Carve Stone".
A photograph of the main structure of a large-scale puppet on a flatbed truck. The puppet is titled The Knight, and was created by Free Theatre Christchurch for Canterbury Tales, which was the main event of FESTA 2013.
Page 3 of Section A of the Christchurch Press, published on Wednesday 14 December 2011.
A PDF copy of The Star newspaper, published on Friday 13 July 2012.
A photograph of the Durham Street Methodist Church on Durham Street. The church has almost completely collapsed and only a small section of the structure is still standing. Masonry and other rubble has spilled onto the footpath and street in front.
Buildings subject to earthquake shaking will tend to move not only horizontally but also rotate in plan. In-plan rotation is known as “building torsion” and it may occur for a variety of reasons, including stiffness and strength eccentricity and/or torsional effects from ground motions. Methods to consider torsion in structural design standards generally involve analysis of the structure in its elastic state. This is despite the fact that the structural elements can yield, thereby significantly altering the building response and the structural element demands. If demands become too large, the structure may collapse. While a number of studies have been conducted into the behavior of structures considering inelastic building torsion, there appears to be no consensus that one method is better than another and as a result, provisions within current design standards have not adopted recent proposals in the literature. However, the Canterbury Earthquakes Royal Commission recently made the recommendation that provisions to account for inelastic torsional response of buildings be introduced within New Zealand building standards. Consequently, this study examines how and to what extent the torsional response due to system eccentricity may affect the seismic performance of a building and considers what a simple design method should account for. It is concluded that new methods should be simple, be applicable to both the elastic and inelastic range of response, consider bidirectional excitation and include guidance for multi-story systems.
Discusses the history, purpose and the structure of the organisation. Also provides links to regional branches, news, newsletters, rural jobs- a resource for prospective employers and employees and resources such as guides, reports and contract and agreement forms. Earthquake related information can be found in the archived instances from September 2010-