Search

found 161 results

Research papers, University of Canterbury Library

This research investigates the validation of simulated ground motions on complex structural systems. In this study, the seismic responses of two buildings are compared when they are subjected to as-recorded ground motions and simulated ones. The buildings have been designed based on New Zealand codes and physically constructed in Christchurch, New Zealand. The recorded ground motions are selected from 40 stations database of the historical 22 Feb. 2011 Christchurch earthquake. The Graves and Pitarka (2015) methodology is used to generate the simulated ground motions. The geometric mean of maximum inter-story drift and peak floor acceleration are selected as the main seismic responses. Also, the variation of these parameters due to record to record variability are investigated. Moreover, statistical hypothesis testing is used to investigate the similarity of results between observed and simulated ground motions. The results indicate a general agreement between the peak floor acceleration calculated by simulated and recorded ground motions for two buildings. While according to the hypothesis tests result, the difference in drift can be significant for the building with a shorter period. The results will help engineers and researchers to use or revise the procedure by using simulated ground motions for obtaining seismic responses.

Images, UC QuakeStudies

A photograph of a Wellington Emergency Management Office Emergency Response Team member talking to a member of the Professional Building Services on Gloucester Street. In the background is the Press House building with many cracks in the façade. Bits of bricks and other debris are scattered across the footpath. Some of the windows above the facade have broken. USAR codes have been spray-painted on one of the bottom-storey windows.

Images, UC QuakeStudies

A photograph of the former City Council Civic Offers at 194-196 Manchester Street. USAR codes have been stray-painted on the windows. A yellow sticker is stuck to the door, indicating that entry to the building is restricted.

Images, UC QuakeStudies

A photograph of the former City Council Civic Offers at 194-196 Manchester Street. USAR codes have been stray-painted on the windows. A yellow sticker is stuck to the door, indicating that entry to the building is restricted.

Images, UC QuakeStudies

A photograph of the Little India building on the corner of Gloucester Street and New Regent Street. One of the doors has been boarded up with plywood. USAR codes and a red sticker can be seen on the other.

Images, UC QuakeStudies

A damaged house in the Christchurch central city. Codes have been spray painted on the driveway as well as "No go" on the front window and door. A red sticker in the front window indicates that the building is unsafe to enter.

Images, UC QuakeStudies

A photograph of the earthquake-damage to St Paul's-Trinity-Pacific Church on Cashel Street. A large section of the left side of the building has collapsed and the rubble has scattered onto the footpath and street below. Scaffolding constructed up the left side has also collapsed. USAR codes have been spray-painted on the wall in front of the building.

Images, UC QuakeStudies

A photograph of the rubble from a demolished building on Bealey Avenue. Tape has been slung over the entrance to the property and a portaloo can be seen to the left of the photograph. USAR codes have been spray-painted on the brick fence.

Images, UC QuakeStudies

A photograph of members of the Wellington Emergency Management Office Emergency Response Team standing in front of an earthquake-damaged building on Lichfield Street. A section of the roof and the façade on the top storey of the building have collapsed and the bricks and other rubble have spilled onto the footpath and street below. USAR codes have been spray-painted on one of the bottom-storey windows and the front door.

Research papers, The University of Auckland Library

Past earthquakes have consistently highlighted the vulnerabilities of the built environment. Current building codes, which focus primarily on life safety, fail to address the need for buildings to remain functional after a seismic event. The emerging concept of post-earthquake functional recovery aims to integrate recovery-based objectives into building codes. However, literature reveals a predominant focus on engineering parameters, with limited attention given to the perspectives of building users; a critical gap in understanding a building’s comprehensive functionality and path to functional recovery. Whilst structural integrity is essential, functionality following a disaster is not determined by physical stability alone. Thus, this study addresses this gap by exploring the perceptions and expectations of office building users (both tenants and property owners) regarding building functionality and post-earthquake functional recovery in New Zealand’s major urban centres: Wellington, Auckland, and Christchurch. A qualitative research strategy was employed, utilising interpretative phenomenological and grounded theory methods to develop insights from the lived experiences of twenty-six (26) participants. The study applied a systems thinking approach using a socio-technical systems (STS) framework to develop micro (single construct) and macro (multiple constructs) models of building-system functionality. The findings demonstrate that a building’s functionality is nuanced, multifaceted, and context dependent. It encompasses physical, economic, social, organisational, technical, regulatory, and environmental elements, and is ultimately determined by users’ specific needs and priorities. A key divergence emerged: whilst property owners prioritise economic and environmental factors, tenants focus on the socio-organisational aspect, viewing the physical workspace as an embodiment of corporate identity, culture, and values. Regarding expectations for post-earthquake functional recovery, the post-pandemic era has drastically reshaped outlooks. Unlike previous earthquakes, where tenants scrambled for any available space, there is now increased demand for flexibility due to the hybrid work model. The immediate return to an office following a major earthquake is now expected to support critical business functions, with essential services including power or a standby generator, technology to access files, water, as well as operations of air conditioning and elevators. By advancing socio-technical systems theory and elucidating building users’ perspectives for a building’s functionality and post-disaster functional recovery, this research provides evidence-based, social science insights to inform more holistic and effective risk governance in property and disaster risk management

Images, UC QuakeStudies

A photograph of a piece of plywood sitting on top of a pile of bricks from the Carlton Hotel. USAR codes have been spray-painted on the wood. In the foreground, metal fencing, cordon tape and a road cone have been used to cordon off the building.

Research papers, The University of Auckland Library

New Zealand's devastating Canterbury earthquakes provided an opportunity to examine the efficacy of existing regulations and policies relevant to seismic strengthening of vulnerable buildings. The mixed-methods approach adopted, comprising both qualitative and quantitative approaches, revealed that some of the provisions in these regulations pose as constraints to appropriate strengthening of earthquake-prone buildings. Those provisions include the current seismic design philosophy, lack of mandatory disclosure of seismic risks and ineffective timeframes for strengthening vulnerable buildings. Recommendations arising from these research findings and implications for pre-disaster mitigation for future earthquake and Canterbury's post-disaster reconstruction suggest: (1) a reappraisal of the requirements for earthquake engineering design and construction, (2) a review and realignment of all regulatory frameworks relevant to earthquake risk mitigation, and (3) the need to develop a national programme necessary to achieve consistent mitigation efforts across the country. These recommendations are important in order to present a robust framework where New Zealand communities such as Christchurch can gradually recover after a major earthquake disaster, while planning for pre-disaster mitigation against future earthquakes AM - Accepted Manuscript

Images, UC QuakeStudies

A photograph of an earthquake-damaged house on Gloucester Street. The bottom storey of the house has shifted and is now on a noticeable lean. USAR codes have been spray-painted on the front of the building and a red sticker has been placed on one of the windows.

Images, UC QuakeStudies

A photograph of Riverview Lodge on Cambridge Terrace. Some of the roof tiles have lifted and cordon tape has been draped across the entrance. USAR codes have been spray-painted in one window and a red sticker taped in another. The red sticker indicates that the building is unsafe to enter.

Research papers, University of Canterbury Library

Research on human behaviour during earthquake shaking has identified three main influences of behaviour: the environment the individual is located immediately before and during the earthquake, in terms of where the individual is and who the individual is with at the time of the earthquake; individual characteristics, such as age, gender, previous earthquake experience, and the intensity and duration of earthquake shaking. However, little research to date has systematically analysed the immediate observable human responses to earthquake shaking, mostly due to data constraints and/or ethical considerations. Research on human behaviour during earthquakes has relied on simulations or post-event, reflective interviews and questionnaire studies, often performed weeks to months or even years following the event. Such studies are therefore subject to limitations such as the quality of the participant's memory or (perceived) realism of a simulation. The aim of this research was to develop a robust coding scheme to analyse human behaviour during earthquake shaking using video footage captured during an earthquake event. This will allow systematic analysis of individuals during real earthquakes using a previously unutilized data source, thus help develop guidance on appropriate protective actions. The coding scheme was developed in a two-part process, combining a deductive and inductive approach. Previous research studies of human behavioral response during earthquake shaking provided the basis for the coding scheme. This was then iteratively refined by applying the coding scheme to a broad range of video footage of people exposed to strong shaking during the Canterbury earthquake sequence. The aim of this was to optimise coding scheme content and application across a broad range of scenarios, and to increase inter-coder reliability. The methodology to code data will enhance objective observation of video footage to allow cross-event analysis and explore (among others): reaction time, patterns of behaviour, and social, environmental and situational influences of behaviour. This can provide guidance for building configuration and design, and evidence-based recommendations for public education about injury-preventing behavioural responses during earthquake shaking.

Images, UC QuakeStudies

A photograph of the earthquake damage to the Avonmore House on the corner of Hereford Street and Latimer Square. Large cracks have formed in the building, causing sections of the masonry to crumble. The windows on the Hereford Street side of the building have bent out of shape and many of the glass panes have shattered. USAR codes have been spray painted on the column next to the door. In the distance wire fencing has been placed across the street as a cordon.

Images, UC QuakeStudies

A photograph of a residential property in the Christchurch central city with USAR codes spray-painted on the driveway and "No go" spray-painted on the front window and door. A red sticker in the window indicates that the building is unsafe to enter. Cordon tape has been draped around the side, cordoning off a pile of bricks.

Images, UC QuakeStudies

A photograph of a car on Gloucester Street which has been crushed by falling bricks from the Canterbury Times and Star building. There is a pile of bricks on the front of the car. A USAR team have spray-painted codes on a plywood board and wedged it into the back of the car.

Images, UC QuakeStudies

A photograph of the earthquake damage to The Burrito Company on Armagh Street. The front window has smashed, the glass spilling onto the floor and footpath outside. USAR codes have been spray-painted on the door and window to the side. A red sticker on the door indicates that the building is unsafe to enter.

Images, UC QuakeStudies

A photograph of the earthquake damage to The Burrito Company on Armagh Street. The front window has smashed, the glass spilling onto the floor and footpath outside. USAR codes have been spray-painted on the door and window to the side. A red sticker on the door indicates that the building is unsafe to enter.

Research papers, University of Canterbury Library

Currently there is a worldwide renaissance in timber building design. At the University of Canterbury, new structural systems for commercial multistorey timber buildings have been under development since 2005. These systems incorporate large timber sections connected by high strength post-tensioning tendons, and timber-concrete composite floor systems, and aim to compete with existing structural systems in terms of cost, constructability, operational and seismic performance. The development of post-tensioned timber systems has created a need for improved lateral force design approaches for timber buildings. Current code provisions for seismic design are based on the strength of the structure, and do not adequately account for its deformation. Because timber buildings are often governed by deflection, rather than strength, this can lead to the exceedence of design displacement limitations imposed by New Zealand codes. Therefore, accurate modeling approaches which define both the strength and deformation of post-tensioned timber buildings are required. Furthermore, experimental testing is required to verify the accuracy of these models. This thesis focuses on the development and experimental verification of modeling approaches for the lateral force design of post-tensioned timber frame and wall buildings. The experimentation consisted of uni-direcitonal and bi-directional quasi-static earthquake simulation on a two-thirds scale, two-storey post-tensioned timber frame and wall building with timber-concrete composite floors. The building was subjected to lateral drifts of up to 3% and demonstrated excellent seismic performance, exhibiting little damage. The building was instrumented and analyzed, providing data for the calibration of analytical and numerical models. Analytical and numerical models were developed for frame, wall and floor systems that account for significant deformation components. The models predicted the strength of the structural systems for a given design performance level. The static responses predicted by the models were compared with both experimental data and finite element models to evaluate their accuracy. The frame, wall and floor models were then incorporated into an existing lateral force design procedure known as displacement-based design and used to design several frame and wall structural systems. Predictions of key engineering demand parameters, such as displacement, drift, interstorey shear, interstorey moment and floor accelerations, were compared with the results of dynamic time-history analysis. It was concluded that the numerical and analytical models, presented in this thesis, are a sound basis for determining the lateral response of post-tensioned timber buildings. However, future research is required to further verify and improve these prediction models.