Search

found 598 results

Images, UC QuakeStudies

Photograph captioned by BeckerFraserPhotos, "Manikin against sculpture in Cathedral Square. This began as light relief for the crews working within the cordon in the weeks after the February earthquake where the manikins were strategically positioned around the red zone at night".

Images, UC QuakeStudies

A montage of photographs of the creation of the installation 'Tonic'. The installation is part of the LUXCITY event. Tutors: Annabel Pretty, Cesar Wagner, Peter McPherson

Images, UC QuakeStudies

A photograph of an installation that forms part of the '60 Lights Market' at the LUXCITY event. Coordinators: Jeongbin Ok, Tiago Rorke, Jonathan Coates; student: Tom Hall

Images, UC QuakeStudies

A photograph of crowds at the LUXCITY event. The photograph shows an installation on Worcester Street, with the new Press building in the background. The installation is titled "Murmur".

Images, UC QuakeStudies

A photograph of an installation on the corner of Gloucester Street and Colombo Street. The installation is titled "Etch-a-Sketch", and is part of the LUXCITY event.

Images, UC QuakeStudies

A photograph of an installation on the corner of Manchester Street and Gloucester Street. The installation is titled "60 Lights Market", and is part of the LUXCITY event.

Research papers, University of Canterbury Library

Field surveys and experimental studies have shown that light steel or timber framed plasterboard partition walls are particularly vulnerable to earthquake damage prompting the overarching objective of this research, which is to further the development of low damage seismic systems for non-structural partition walls in order to facilitate their adoption by industry to assist with reducing the losses associated with the maintenance and repair cost of buildings across their design life. In particular, this study focused on the behaviour of steel-framed partition walls systems with novel detailing that aim to be “low-damage” designed according to common practice for walls used in commercial and institutional buildings in New Zealand. This objective was investigated by (1) investigating the performance of a flexible track system proposed by researchers and industry by experimental testing of full-scale specimens; (2) investigating the performance of the seismic gap partition wall systems proposed in a number of studies, further developed in this study with input from industry, by experimental testing of full-scale specimens; and (3) investigating the potential implications of using these systems compared with traditionally detailed partition wall systems within multi-storey buildings using the Performance Based Earthquake Engineering loss assessment methodology. Three full-scale testing frames were designed in order to replicate, under controlled laboratory conditions, the effects of seismic shaking on partition walls within multi-storey buildings by the application of quasi-static uni-directional cyclic loading imposing an inter-storey drift. The typical configuration for test specimens was selected to be a unique “y-shape”, including one angled return wall, with typical dimensions of approximately 2400 mm along the main wall and 600 mm along (approximately) the returns walls with a height of 2405 mm from floor to ceiling. The specimens were aligned within test frames at an oblique angle to the direction of loading in order to investigate bi- directional effects. Three wall specimens with flexible track detailing, two identical plane specimens and the third including a doorway, were tested. The detailing involved removing top track anchors within the proximity of wall intersections, thus allowing the tracks to ‘bow’ out at these locations. Although the top track anchors were specified to be removed the proximity of wall intersections, a construction error was made whereby a single top track slab to concrete anchor was left in at the three-way wall junction. Despite this error, the experimental testing was deemed worthwhile since such errors will also occur in practice and because the behaviour of the wall can be examined with this fixing in mind. The specimens also included an acoustic/fire sealant at the top lining to floor boundary. In addition to providing drift capacities, the force-displacement behaviour is also reported, the dissipated energy was computed, and the parameters of the Wayne-Stewart hysteretic model were fitted to the results. The specimen with the door opening behaved significantly different to the plane specimens: damage to the doorway specimen began as cracking of the wallboard propagating from the corners of the doorway following which the L- and Y- shaped junctions behaved independently, whereas damage to the plane specimens began as cracking of the wallboard at the top of the L-junction and wall system deformed as a single unit. The results suggest that bi-directional behaviour is important even if its impact cannot be directly quantified by the experiments conducted. Damage to sealant implies that the bond between plasterboard and sealant is important for its seismic performance. Careful quality control is advised as defects in the bond may significantly impact its ability to withstand seismic movement. Two specimens with seismic gap detailing were tested: a steel stud specimen and a timber stud specimen. Observed drift capacities were significantly greater than traditional plasterboard partition systems. Equations were used to predict the drift at which damage state 1 (DS1) and damage state 2 (DS2) would initiate. The equation used to estimate the drift at the onset of DS1 accurately predicted the onset of plaster cracking but overestimated the drift at which the gap filling material was damaged. The equation used to predict the onset of DS2 provided a lower bound for both specimens and also when used to predict results of previous experimental tests on seismic gap systems. The gap-filling material reduced the drift at the onset of DS1, however, it had a beneficial effect on the re-centring behaviour of the linings. Out-of-plane displacements and return wall configuration did not appear to significantly impact the onset of plaster cracking in the specimens. A loss assessment according to the PBEE methodology was conducted on four steel MRF case study buildings: (1) a 4-storey building designed for the Christchurch region, (2) a 4-storey building designed for the Wellington region, (3) a 12-storey building designed for the Christchurch region, and (4) a 12- storey building designed for the Wellington region. The fragility parameters for a traditional partition system, the flexible track partition system, and the seismic gap steel stud and timber stud partition systems were included within the loss assessment. The order (lowest to highest) of each system in terms of the expected annual losses of each building when incorporating the system was, (1) the seismic gap timber stud system, (2) the seismic gap steel stud system, (3) the traditional/baseline system, and (4) the flexible track system. For the seismic gap timber stud system, which incurred the greatest reduction in expected annual losses for each case study building, the reduction in expected annual losses in comparison to the losses found when using the traditional system ranged from a 5% to a 30% reduction. This reinforces the fact that while there is a benefit to the using low damage partition systems in each building the extent of reduction in expected annual losses is significantly dependent on the particular building design and its location. The flexible track specimens had larger repair costs at small hazard levels compared to the traditional system but smaller repair costs at larger hazard levels. However, the resulting expected annual losses for the flexible track system was higher than the traditional system which reinforces findings from past studies which observed that the greatest contribution to expected annual losses arises from low to moderate intensity shaking seismic events (low hazard levels).

Research papers, University of Canterbury Library

Light timber framed (LTF) structures provide a cost-effective and structurally efficient solution for low-rise residential buildings. This paper studies seismic performance of single-storey LTF buildings sheathed by gypsum-plasterboards (GPBs) that are a typical lining product in New Zealand houses. Compared with wood-based structural panels, GPBs tend to be more susceptible to damage when they are used in bracing walls to resist earthquake loads. This study aims to provide insights on how the bracing wall irregularity allowed by the current New Zealand standard NZS 3604 and the in-plane rigidity of ceiling diaphragms affect the overall seismic performance of these GPB-braced LTF buildings. Nonlinear time-history analyses were conducted on a series of single-storey baseline buildings with different levels of bracing wall irregularities and ceiling diaphragm rigidity. The results showed significant torsional effect caused by the eccentric bracing wall layout with semi-rigid/rigid ceiling diaphragms. On average, bracing wall drift demand caused by the extreme bracing wall irregularities was three times of that in the regular bracing wall layout under the rigid diaphragm assumption. This finding agreed well with the house survey after the 2011 Canterbury Earthquake in which significantly more damage was observed in the houses with irregular bracing wall layouts and relatively rigid diaphragms. Therefore, it is recommended to limit the level of bracing wall eccentricity and ensure the sufficiently rigid diaphragms to avoid excessive damage in these LTF buildings in future events.

Images, UC QuakeStudies

An artist's impression of an installation that forms part of the '60 Lights Market' at the LUXCITY event. Coordinators: Daniele Abreu e Lima and Sam Stringlen; students: Chi Tran, Aria Jansen, Naomi Snelling, Rebecca Wyborn

Images, UC QuakeStudies

An artist's impression of an installation that forms part of the '60 Lights Market' at the LUXCITY event. Coordinators: Daniele Abreu e Lima and Michael Smith; students: Alex Heperi, Gagan Saini, Shamal Nanji, Xavier Apelinga

Research papers, University of Canterbury Library

The 1995 book, “Wellington after the quake: the challenge of rebuilding cities”, is reviewed in light of the 2010/2011 Canterbury, New Zealand, earthquakes. Lessons are drawn related to the difficulties of recovery of complex infrastructure systems after disasters.

Research papers, University of Canterbury Library

Context of the project: On 4 September 2010, 22 February 2011, 13 June 2011 and 23 December 2011 Christchurch suffered major earthquakes and aftershocks (well over 10,000) that have left the central city in ruins and many of the eastern suburbs barely habitable even now. The earthquakes on 22 February caused catastrophic loss of life with 185 people killed. The toll this has taken on the residents of Christchurch has been considerable, not least of all for the significant psychological impact and disruption it has had on the children. As the process of rebuilding the city commenced, it became clear that the arts would play a key role in maintaining our quality of life during difficult times. For me, this started with the children and the most expressive of all the art forms – music.

Images, UC QuakeStudies

A photograph of installations being constructed on the corner of Gloucester Street and Colombo Street for the LUXCITY event. In the foreground is the installation titled "In Your Face", and to the right is the installation titled "Etch-a-Sketch".

Images, Canterbury Museum

One official black and yellow coloured uniform, comprising overalls, boots, helmet, goggles, ear protectors and head light, worn by the New Zealand Fire Service Urban Search and Rescue (USAR) team in the aftermath of the 22 February 2011 earthquake. 'USAR' in yellow letters on the back of the overalls. This uniform was worn by Paul Burns, who w...

Images, eqnz.chch.2010

Light-Relief - With no power after the 6.3 magnatude quake hit Christchurch (22 February 2011) the neighbour's freezer thawed out along with their Deep South Ice Cream - so Tiggles the Kunekune Piglet thinks the spoils of the power-cut are yummy!

Audio, Radio New Zealand

Sixteen-year-old Sam Mackwell and his mates from St Thomas of Canterbury College have created a device that uses boiling water to charge cellphones, power a light and run a radio. They came up with the idea for the small generator after the first earthquake in Canterbury in September when electricity supplies were cut to much of the city. They call the device"The Lion"and hope to sell it in retail stores soon.

Articles, UC QuakeStudies

An PDF copy of a poster featuring Northcote resident Sandy Otunfangavalu. The poster quotes Otufangavalu: "I am grateful for my kids and family, who light up my life and help keep me grounded." The poster is from the All Right? I am ... Identity project, which sought to celebrate identity and its importance to Pacific youth and their wellbeing.

Images, UC QuakeStudies

A photograph of crowds at the LUXCITY event. The photograph shows installations on the corner of Gloucester Street and Colombo Street. In the foreground is the installation titled "In Your Face", and to the right is the installation titled "Etch-a-Sketch".

Research papers, University of Canterbury Library

Very little research exists on total house seismic performance. This testing programme provides stiffness and response data for five houses of varying ages including contributions of non-structural elements. These light timber framed houses in Christchurch, New Zealand had minor earthquake damage from the 2011 earthquakes and were lateral load tested on site to determine their strength and stiffness, and preliminary damage thresholds. Dynamic characteristics were also investigated. Various loading schemes were utilised including quasi-static loading above the foundation, unidirectional loading through the floor diaphragm, cyclic quasi-static loading and snapback tests. Dynamic analysis on two houses provided the seismic safety levels of post-quake houses with respect to local hazard levels. Compared with New Zealand Building Standards all the tested houses had an excess of strength, damage is a significant consideration in earthquake resilience and was observed in all of the houses. A full size house laboratory test is proposed.

Videos, UC QuakeStudies

A video of an interview with Defence Counsel Jonathan Eaton about the police's refusal to allow diversion for alleged-looter Cornelius Arie Smith-Voorkamp. Smith-Voorkamp was arrested for allegedly taking light fittings from an earthquake-damaged property on Lincoln Road. Diversion was applied for on the basis that Smith-Voorkamp has autism, and his Asperger's syndrome involves a compulsion to take electrical fittings.

Images, eqnz.chch.2010

On a walk over to Hagley Park to great some shots of the wonderful Cherry Blossom I past by the Knox Church rebuild and found that the scaffolding has come down at last. It sure was shinning in the midday light. Victoria Street September 12, 2014 Christchurch New Zealand

Images, UC QuakeStudies

A scanned copy of a black and white photograph of the He-Ne Continuous Gas Laser used in David Lockwood's MSc research at the University of Canterbury. David says, "The experiments in the Thesis were aimed at examining the effects of sound waves on colloids, which are very small particles that are found in clays for example (for more details see page 181 of http://www.cap.ca/PiC-PaC/static/downloads/1efdc1f3784b85c1a1b33e396b91ee8aef2072c5.pdf ). In fact, I was looking at nanoparticles of matter, which preceded the emergence of nanotechnology as a field of research by more than two decades. I needed a suitable light source to probe the alignment of the nanoparticles in the ultrasonic sound field. At that time the laser had just been invented and I realized that this was the ideal light source for my experiment. I then proceeded to construct the first home-built laser in New Zealand. This laser - a He-Ne continuous-wave gas laser - operated at 632.8 nm (in the red). This laser, over a metre long, is shown in the black-and-white photo. There were lot of problems to be overcome, but eventually, with invaluable help from Dr. Tom Seed (my MSc supervisor) and Dr. Rod Syme, I had it working".

Research papers, University of Canterbury Library

Seismic isolation is an effective technology for significantly reducing damage to buildings and building contents. However, its application to light-frame wood buildings has so far been unable to overcome cost and technical barriers such as susceptibility to movement during high-wind loading. The precursor to research in the field of isolation of residential buildings was the 1994 Northridge Earthquake (6.7 MW) in the United States and the 1995 Kobe Earthquake (6.9 MW) in Japan. While only a small number of lives were lost in residential buildings in these events, the economic impact was significant with over half of earthquake recovery costs given to repair and reconstruction of residential building damage. A value case has been explored to highlight the benefits of seismically isolated residential buildings compared to a standard fixed-base dwellings for the Wellington region. Loss data generated by insurance claim information from the 2011 Christchurch Earthquake has been used by researchers to determine vulnerability functions for the current light-frame wood building stock. By further considering the loss attributed to drift and acceleration sensitive components, and a simplified single degree of freedom (SDOF) building model, a method for determining vulnerability functions for seismic isolated buildings was developed. Vulnerability functions were then applied directly in a loss assessment using the GNS developed software, RiskScape. Vulnerability was shown to dramatically reduce for isolated buildings compared to an equivalent fixed-base building and as a result, the monetary savings in a given earthquake scenario were significant. This work is expected to drive further interest for development of solutions for the seismic isolation of residential dwellings, of which one option is further considered and presented herein.