Base isolation is an incredibly effective technology used in seismic regions throughout the world to limit structural damage and maintain building function, even after severe earthquakes. However, it has so far been underutilised in light-frame wood construction due to perceived cost issues and technical problems, such as a susceptibility to movement under strong wind loads. Light-frame wood buildings make up the majority of residential construction in New Zealand and sustained significant damage during the 2010-2011 Canterbury earthquake sequence, yet the design philosophy has remained largely unchanged for years due to proven life-safety performance. Recently however, with the advent of performance based earthquake engineering, there has been a renewed focus on performance factors such as monetary loss that has driven a want for higher performing residential buildings. This research develops a low-cost approach for the base isolation of light-frame wood buildings using a flat-sliding friction base isolation system, which addresses the perceived cost and technical issues, and verifies the seismic performance through physical testing on the shake table at the University of Canterbury. Results demonstrate excellent seismic performance with no structural damage reported despite a large number of high-intensity earthquake simulations. Numerical models are subsequently developed and calibrated to New Zealand light-frame wood building construction approaches using state-of-the-art wood modelling software, Timber3D. The model is used to accurately predict both superstructure drift and acceleration demand parameters of fixed-base testing undertaken after the base isolation testing programme is completed. The model development allows detailed cost analyses to be undertaken within the performance based earthquake engineering framework that highlights the monetary benefits of using base isolation. Cost assessments indicate the base isolation system is only 6.4% more compared to the traditional fixed-base system. Finally, a design procedure is recommended for base isolated light-frame wood buildings that is founded on the displacement based design (DBD) approach used in the United States and New Zealand. Nonlinear analyses are used to verify the DBD method which indicate its suitability.
Light timber framed (LTF) structures provide a cost-effective and structurally efficient solution for low-rise residential buildings. This paper studies seismic performance of single-storey LTF buildings sheathed by gypsum-plasterboards (GPBs) that are a typical lining product in New Zealand houses. Compared with wood-based structural panels, GPBs tend to be more susceptible to damage when they are used in bracing walls to resist earthquake loads. This study aims to provide insights on how the bracing wall irregularity allowed by the current New Zealand standard NZS 3604 and the in-plane rigidity of ceiling diaphragms affect the overall seismic performance of these GPB-braced LTF buildings. Nonlinear time-history analyses were conducted on a series of single-storey baseline buildings with different levels of bracing wall irregularities and ceiling diaphragm rigidity. The results showed significant torsional effect caused by the eccentric bracing wall layout with semi-rigid/rigid ceiling diaphragms. On average, bracing wall drift demand caused by the extreme bracing wall irregularities was three times of that in the regular bracing wall layout under the rigid diaphragm assumption. This finding agreed well with the house survey after the 2011 Canterbury Earthquake in which significantly more damage was observed in the houses with irregular bracing wall layouts and relatively rigid diaphragms. Therefore, it is recommended to limit the level of bracing wall eccentricity and ensure the sufficiently rigid diaphragms to avoid excessive damage in these LTF buildings in future events.
To this extent, modern buildings generally demonstrated good resistance to collapse during the recent earthquakes in New Zealand. However, damage to non-structural elements (NSE) has been persistent during these events. NSEs include secondary systems or components attached to the floors, roofs, and walls of a building or industrial facility that are not explicitly designed to participate in the main vertical or lateral load-bearing mechanism of the structure. They play a major role in the operational and functional aspects of buildings and contribute a major portion of the building’s overall cost. Therefore, they are expected to accommodate the effects of seismic actions such as drifts and accelerations. Typical examples of NSEs include internal non-loadbearing partitions, suspended ceilings, sprinkler piping systems, architectural claddings, building contents, mechanical/electrical equipment, and furnishings. The main focus of this thesis is the drift sensitive NSEs: precast concrete cladding panels and internal partition walls. Even though most precast concrete cladding panels performed well from a life-safety point of view during recent earthquakes in NZ, some collapsed panels posed a significant threat to life safety. It is, therefore, important that the design and detailing of the panel-to-structure connections ensure that their strength and displacement capacity are adequate to meet the corresponding seismic demands, at least during design level earthquakes. In contrast, the partition wall is likely to get damaged and lose serviceability at a low inter-story drift unless designed to accommodate the relative deformations between them and the structure. Partition walls suffered wide-ranging damage such as screw failures, diagonal cracking, detachments to the gypsum linings, and anchorage failures during the 2011 Canterbury Earthquake Sequence in NZ. Therefore, the thesis is divided into two parts. Part I of the thesis focuses on developing novel low-damage precast concrete cladding panel connections, i.e. “rocking” connection details comprising vertically slotted steel embeds and weld plates. The low-damage seismic performance of novel “rocking” connection details is verified through experimental tests comprising uni-directional, bi-directional, and multi-storey scaled quasi-static cyclic tests. Comparison with the seismic performance of traditional panel connections reported in the literature demonstrated the system’s significantly improved seismic resilience. Furthermore, the finite element models of panel connections and sealants are developed in ABAQUS. The force-drift responses of the “rocking” panel system modelled in SAP2000 is compared with the experimental results to evaluate their accuracy and validity. Part II of the thesis focuses on a) understanding the seismic performance of traditional rigid timber-framed partition wall, b) development and verification of low-damage connections (i.e. “rocking” connection details comprising of dual-slot tracks), and c) seismic evaluation of partition walls with a novel “bracketed and slotted” connections (comprising of innovative fastener and plastic bracket named Flexibracket) under uni-directional and bidirectional quasi-static cyclic loadings. Moreover, parametric investigation of the partition walls was conducted through several experimental tests to understand better the pros and cons of the rocking connection details. The experimental results have confirmed that the implementation of the proposed low damage solutions of precast cladding panels and internal partition walls can significantly reduce their damage in a building.
Rapid, reliable information on earthquake-affected structures' current damage/health conditions and predicting what would happen to these structures under future seismic events play a vital role in accelerating post-event evaluations, leading to optimized on-time decisions. Such rapid and informative post-event evaluations are crucial for earthquake-prone areas, where each earthquake can potentially trigger a series of significant aftershocks, endangering the community's health and wealth by further damaging the already-affected structures. Such reliable post-earthquake evaluations can provide information to decide whether an affected structure is safe to stay in operation, thus saving many lives. Furthermore, they can lead to more optimal recovery plans, thus saving costs and time. The inherent deficiency of visual-based post-earthquake evaluations and the importance of structural health monitoring (SHM) methods and SHM instrumentation have been highlighted within this thesis, using two earthquake-affected structures in New Zealand: 1) the Canterbury Television (CTV) building, Christchurch; 2) the Bank of New Zealand (BNZ) building, Wellington. For the first time, this thesis verifies the theoretically- and experimentally validated hysteresis loop analysis (HLA) SHM method for the real-world instrumented structure of the BNZ building, which was damaged severely due to three earthquakes. Results indicate the HLA-SHM method can accurately estimate elastic stiffness degradation for this reinforced concrete (RC) pinched structure across the three earthquakes, which remained unseen until after the third seismic event. Furthermore, the HLA results help investigate the pinching effects on the BNZ building's seismic response. This thesis introduces a novel digital clone modelling method based on the robust and accurate SHM results delivered by the HLA method for physical parameters of the monitored structure and basis functions predicting the changes of these physical parameters due to future earthquake excitations. Contrary to artificial intelligence (AI) based predictive methods with black-box designs, the proposed predictive method is entirely mechanics-based with an explicitly-understandable design, making them more trusted and explicable to stakeholders engaging in post-earthquake evaluations, such as building owners and insurance firms. The proposed digital clone modelling framework is validated using the BNZ building and an experimental RC test structure damaged severely due to three successive shake-table excitations. In both structures, structural damage intensifies the pinching effects in hysteresis responses. Results show the basis functions identified from the HLA-SHM results for both structures under Event 1 can online estimate structural damage due to subsequent Events 2-3 from the measured structural responses, making them valuable tool for rapid warning systems. Moreover, the digital twins derived for these two structures under Event 1 can successfully predict structural responses and damage under Events 2-3, which can be integrated with the incremental dynamic analysis (IDA) method to assess structural collapse and its financial risks. Furthermore, it enables multi-step IDA to evaluate earthquake series' impacts on structures. Overall, this thesis develops an efficient method for providing reliable information on earthquake-affected structures' current and future status during or immediately after an earthquake, considerably guaranteeing safety. Significant validation is implemented against both experimental and real data of RC structures, which thus clearly indicate the accurate predictive performance of this HLA-based method.
Ongoing climate change triggers increasing temperature and more frequent extreme events which could limit optimal performance of haliotids, affect their physiology and biochemistry as well as influencing their population structure. Haliotids are a valuable nearshore fishery in a number of countries and many are showing a collapse of stocks because of overexploitation, environmental changes, loss of habitat, and disease. The haliotid in New Zealand commonly referred to as the blackfoot pāua (Haliotis iris) contribute a large and critical cultural, recreational and economic resource. Little was known about pāua responses to increasing temperature and acute environmental factors, as well as information about population size structure in Kaikoura after the earthquake 2016 and in Banks Peninsula. The aims of this study were to investigate the effects of temperature on scope for growth (SfG); physiological and biochemical responses of pāua subjected to different combined stressors including acute temperature, acute salinity and progressive hypoxia; and describe population size structure and shell morphology in different environments in Kaikoura and Banks Peninsula. The main findings of the present study found that population size structures of pāua were site-specific, and the shell length and shell height ratio of 3.25 could distinguish between stunted and non-stunted populations. The study found that high water temperature resulted in a reduction in absorbed energy from food, an increase in respiration energy, and ammonia excretion energy. Surveys were conducted at six study sites around the Canterbury Region over three years in order to better understand the population size structure and shell morphology of pāua. The findings found that the population size structure at 6 sites differed. Both juveniles and adults were found in intertidal areas at five sites. However, at Cape Three Points, pāua were found only in subtidal zones. One of the sites, Little Port Cooper, had a stunted population where only two pāua reached 125 mm in length over three years. In addition, most pāua in Little Port Cooper and Cape Three Points were adults, while Seal Reef had mostly juveniles. Wakatu Quay and Omihi had a full size range of pāua. Oaro population was dominated with juveniles and sub-adults. Recruitment and growth of pāua were successful after the earthquake in 2016. Research into pāua shell morphologies also determined that shell dimensions differed between sites. The relationships of shell length to shell width were linear and the relationship of shell length to shell height was curvilinear. Interestingly, SL:SH ratio of 3.25 is able to be used to identify stunted and non-stunted populations for pāua larger than 90 mm in length. Little Port Cooper was a stunted population with mean SL:SH ratio being 3.16. In the laboratory, scope for growth of pāua was investigated at four different temperatures of 12oC, 15oC, 18oC and 21oC over four weeks’ acclimation. The current study has found that SfG of pāua highly depended on temperature. Absorbed energy and respiration energy accounted for the highest proportion of the SfG of pāua. The respiration energy of pāua accounted for approximately 36%, 40%, 49% and 69% of the absorbed energy at 12°C, 15°C, 18°C and 21°C, respectively. The pāua at all acclimation temperatures had a positive scope for growth. The study suggested that the SfG was highest at 15°C, while the value at 21°C was the lowest. However, SfG at 18°C and 21°C decreased after 14 days of acclimation. Because of maintaining almost unchanged oxygen consumption over four weeks’ acclimation, pāua showed their poor abilities to acclimate to an increase in temperature. Therefore, they may be more vulnerable in future warming scenarios. The physiological and biochemical responses of pāua toward different combined stressors included three experiments. In terms of the acute temperature experiment, pāua were acclimated at 12oC, 15oC, 18oC or 21oC for two weeks before stepwise exposure to four temperatures of 12oC, 15oC, 18oC and 21oC every 4 hours. The acute salinity change, pāua were acclimated at 12oC, 15oC or 18oC over two weeks. Pāua were then exposed to a stepwise decrease of salinity of 2‰ every two hours from 34 – 22‰. Regarding the declining oxygen level, pāua were acclimated at 15 oC or 18oC for two weeks before exposure to one of four temperatures at 12oC, 15oC, 18oC or 21oC in one hour. After that acute progressive hypoxia was studied in closed respirometers for around six hours. The findings showed that there were interactions between combined stressors, affecting physiology of pāua (metabolism and heart rate). This suggests that environmental factors do not have a separate effect, but they also have interactions that enhance negative effects on pāua. Also, both oxygen uptake and heart rate responded quickly to temperature change and increased with rising temperature. On the other hand, oxygen uptake and heart rate decreased with reducing salinity and progressive hypoxia (before critical oxygen tension - Pcrit). Pcrit over four acute temperature exposures, ranged between 30.2 and 80.0 mmHg, depending on the exposure temperature. Acclimation temperature, combined with acute temperature, salinity or hypoxia stress affected the biochemistry of pāua. Pāua are osmoconformers so decreased salinity resulted in reducing haemolymph ionic concentration and increasing body volume. They were hypo-ionic with respect to sodium and potassium over the salinity ranges of 34 - 22‰. Haemocyanin accounts for a large pecentage of haemolymph protein, so trends of protein followed haemocyanin. Pāua tended to store oxygen in haemocyanin under extreme salinity stress at 22‰ and extreme hypoxia around 10 mmHg, rather than in oxygen transport. In conclusion, pāua at different sites had different population structures and morphologies. Pāua are sensitive to environmental stressors. They consumed more oxygen at high temperatures because they do not have thermal acclimation capacity. They are also osmoconformers with haemolymph sodium and potassium decreasing with salinity medium. Under progressive hypoxia, pāua could regulate oxygen and heart rate until Pcrit depending on temperature. Acute environmental changes also disturbed haemolyph parameters. 12°C and 15°C could be in the range of optimal temperature with higher SfG and less stress when exposed to acute environmental changes. Meanwhile long term exposure to 21°C is likely to be outside of the optimal range for the pāua. With ongoing climate change, pāua populations are more vulnerable so conservation is necessary. The research contributes to improving fishery management, providing insights into different environmental stressors affecting the energy demand and physiological and biochemical responses of pāua. It also allow to predicting the growth patterns and responses of pāua to adapt to climate change.